1. High-brightness, ultra-clear 4.3-inch colour LCD display: Display resolution: 480×272 pixels, capable of displaying multiple parameters simultaneously.

2. Dual display: Displays direct-read test values alongside relative deviation (△%), ABS%, sorting results, insulation resistance, and leakage current in dual display mode.

3. Multiple trigger modes: Internal trigger, external trigger, foot switch, and interface trigger.

4. Calibration function: Full-range open-circuit zeroing function.

5. Four-level comparison function: Three levels pass, one level fail.

6. Comparator (sorting) function: Built-in with three sorting data levels, capable of performing HI/LOW judgment on the tested item.




Product Detail

Technical Specifications:

1、Screen: High brightness, ultra-clear 4.3-inch colour LCD display: Display pixels: 480*272.

2、Display range: Four-digit display of resistance value.

3、Test parameters: insulation resistance, microcurrent

4、Range: Seven ranges, manual or automatic mode.

5、Basic accuracy: 10K-10T (I > 10nA ±2%, I < 10nA ±5%, I < 1nA ±10%)

6、Insulation resistance measurement range:

CH2683A: 10 kΩ to 10 TΩ; resolution: 0.1 × 103 Ω to 0.1 × 1013 Ω

CH2683B: 10 kΩ to 0.5 TΩ; resolution: 0.1 × 103 Ω to 0.1 × 1013 Ω

Resistivity: 1.0×103 to 1.0×1013 Ω-m; Resolution: 0.1×103 to 0.1×1013 Ω-m

7、Test voltage range: 0.5V to 1000V

8、Test speed: Fast: 12 times/second; Slow: 5 times/second.

9、Test end: 3-end shielding and external shielding ground end.


Product Model

CH2683ACH2683B
Test Parametersinsulation resistance(IR)、

microcurrent(I)

insulation resistance(IR)、microcurrent(I)
Measuring RangeResistance:10KΩ-10TΩ
Current:0.01nA~1mA

Resistance:10KΩ-5TΩ

Current:0.01nA~1mA

Current AccuracyI>10nA: ±2%I≤10nA: ±5%I≤1nA: ±10%I>10nA: ±2%I≤10nA: ±5%I≤1nA: ±10%
Resistance Accuracy10K-10T Calculated based on the accuracy of the current
Voltage range0.5-1000V0.5-500V
Voltage accuracy

Voltage≥10V ±0.25%+0.5V

Voltage<10V ±1%+0.5V

Voltage≥10V ±0.25%+0.5V
Voltage<10V ±1%+0.5V
Readback voltage accuracy±0.25%+0.25V±0.25%+0.25V